Ultrasonic measurement Time-of-Flight Prosonic FMU90
Field of Application :
The Prosonic FMU90 is designed for continuous, non-contact level measurement of:
- Fluids, pastes, sludge, and powdery to coarse bulk solids
- Flow measurement in open channels and weirs
- Simultaneous level and flow measurement in stormwater overflow basins using a single sensor
It supports 1 or 2 sensors, allowing for:
- Level measurement up to 45m (148ft)
- Level limit detection
- Pump and rake control with an optional additional pump control function
Key Specifications :
- Up to 6 relays for:
- Tendency alarm
- Flow pulse output
- Backwater/sludge alarm
- Calculations:
- Flow measurement applications:
- Open channels and weirs with 1 or 2 sensors
- Flow measurement with backwater or sludge detection
- Additional features:
- Up to 3 totalizers and 3 counters
- Counting or time pulse output for external unit control
Key Features & Benefits :
User-Friendly Operation
- Simple, menu-guided operation via a 6-line plain text display
- 15 selectable languages
- "FieldCare" operating program for easy setup, diagnosis, and documentation
Advanced Monitoring & Diagnostics
- On-screen envelope curve display for real-time diagnostics
- Time-of-Flight correction via integrated or external temperature sensors
Optimized for Flow Measurement
- Pre-programmed flumes and weirs with freely configurable linearization (up to 32 points)
- Online calculation of flow rates using integrated flow curves
Automatic Sensor Detection
- Compatible with FDU9x sensors for seamless setup and operation